Troubleshooting: Atwood Slideout Room System
Troubleshooting: Atwood Slideout Room System
Problem | Possible Cause | Correction |
| Room fails to operate when control switch is pressed | Control button not pressed Room already fully extended or retracted Inadequate electrical power | Press the button Press the control button in both directions to verify if room is already fully extended or retracted Check 12-volt battery under load. If voltage is lower than 9 volts, replace the battery. While pressing the On and In buttons simultaneously, check the voltage at the motor with a volt meter. If no voltage, the problem is in the buttons, control or wiring. Check all system wiring, looking for broken connection. |
| Room runs slowly | Inadequate electrical power | Check 12-volt battery voltage. If voltage is lower than 9 volts, charge or replace battery. |
| Room stops prematurely | Control Inadequate electrical power | Release In/Out button, pause 2- 3 seconds then press again. Check 12-volt battery under load. If voltage is lower than 9 volts, replace the battery. |
| Repetative metallic sound | Physical interference | Inspect underside of R.V. to look for cross shaft obstruction |
| Room fails to seal | Stop-screw adjustment | Adjust stop screws to provide for sufficient room travel to allow seals to compress 1/4 to 3/4 inch |
| Room is extended and will not retract | Power failure | Rotate 3/4-inch hex drive in opposite direction of the arrow to manually retract the room. Disconnect wire nuts at motor and use an auxiliary 12-volt battery to apply voltage to the motor. If room operates in wrong direction, reverse the polarity. |