Problem | Possible Cause | Correction |
| Range pilot won't light or stay lit | Gas pressure incorrect Supply valve closed Insufficient gas supply Insufficient gas pressure Blocked pilot orifice or blocked flash tubes Pilot flame too high or too low Pilot flame cover out of position | Set pressure to 11" WC with two or more gas appliances running Turn valve on Check gas supply Check for gas leaks and have regulator checked by qualified LP gas technician Clean pilot orifice with toothpick; clean flash tubes Adjust pilot flame Reposition pilot flame, cover and/ or remove carbon buildup |
| Burner(s) won't light or stay lit | Insufficient gas pressure Incorrect air/gas mixture Blocked orifice | Check for gas leaks and have regulator ckecked by qualified LP gas technician Adjust air shutter Clean with toothpick |
| Burner lights but flame is too small | Improper gas pressure Improper air/gas mixture Problem burner valve Blocked orifice | Check for gas leaks and have regulator checked by qualified LP gas technician Adjust air shutter (on range pilot models only) Replace burner valve Clean with toothpick |
| Burner flame lifts off burner head | Gas pressure too high | Have regulator checked by qualified LP gas technician |
| Oven burner lights, but flame remains very small and oven heats very slowly | Improper gas pressure Blocked orifice | Check for gas leaks and have regulator checked by qualified LP gas technician Clean with alcohol and cotton swab |
| Oven-burner flame lifts off burner and oven cycles too frequently | Gas pressure too high | Have regulator checked by qualified LP gas technician |
| Oven cooks unevenly and/or food burns on the bottom | Poor ventilation Problem thermostat | Oven too full for proper circulation and/or ventilation holes in oven bottom (shelf above burner) are covered Replace thermostat |
| Oven pilot outage | Thermocouple out of position Problem thermostat Blocked oven vent Oncorrect oven burner gas/air mixture | Reposition thermocouple/safety valve Replace thermostat Remove obstruction from vent Readjust air |